T-Sens EMG sensor

Wireless sensor for surface electromyography (sEMG) measurement

The T-Sens EMG-2 sensor is designed for accurate surface electromyography (sEMG) measurements, providing reliable analysis of muscle activity. Enables evaluation of muscle load, fatigue, and imbalance to optimize workstation design and prevent MSDs.


It features onboard RMS value computation, allowing real-time signal processing directly from the sensor.

With an internal sampling rate of 2000 Hz (2 kHz), the T-Sens EMG-2 captures detailed muscle signals with high fidelity. The sensor also records raw EMG data to internal memory, enabling in-depth post-analysis and data integrity.

Specifications

Dimensions

45 mm x 35 mm x 20 mm

Weight

30g sensor only, 36g with electrodes

Sampling rate

128-1024-2048 hz

Gain

665-1330 – 1995 – 3989 μV

Resolution

16 bits

Real-time recording

YES – up to 10m

Embedded memory recording

YES

Output data

raw data (2048 Hz) and RMS (128 Hz)

Battery life

typically 8 hours

Charging time

typically 3 hours

Requires

T-Rec, charging dock, and CAPTIV L7000 software or T-Server

Typical applications

  • Muscle load measurement during repetitive tasks
  • Evaluation of exoskeleton or ergonomic tool effectiveness
  • Fatigue and muscle recovery assessment …

Intended users

  • Ergonomists, workstation designers,
  • physiology researchers,
  • developers of assistive technologies…

Related Products

Placeholder

Measurement synchronization platform for human behavior analysis – Observe and Analyze

Placeholder

Observation and activity analysis software – Chronicle of activities, behavioral analysis, work cycle, etc.

Placeholder

Activity Analysis, the new module that will enable you to obtain all your activity logs automatically by AI.

Placeholder

CAPTIV Score integrates the methods OCRA, RULA and NIOSH to objectify ergonomic assessment.

Placeholder

Observation and activity analysis software – Chronicle of activities, behavioral analysis, work cycle, etc.

Spezifikationen und andere Informationen können ohne vorherige Ankündigung geändert werden. Alle Marken- und Produktnamen sind Warenzeichen oder eingetragene Warenzeichen ihrer jeweiligen Inhaber. Die Informationen auf dieser Webseite werden von den jeweils genannten Herstellern bereitgestellt und dienen der allgemeinen Information. Diese Angaben stellen nur dann eine konkrete Beschaffenheitsangabe dar, wenn sie von EST ausdrücklich angegeben oder schriftlich als Beschaffenheit vereinbart werden.

Adresse:

Wilhelm-Raabe-Str. 6
67663 Kaiserslautern, Germany

E-Mail:

sales@est-kl.com

Öffnungszeiten:

Mon-Fri: 8:30 – 17:30 CET

Nach oben scrollen
Diese Website ist auf wpml.org als Entwicklungsseite registriert. Wechseln Sie zu einem Produktions-Website-Schlüssel, um remove this banner.